PPT Slide
Acknowledgment: This MH-based system was fabricated with the assistance of Uei-kiki Ltd. (vessels) and KOUEI Metal Works Co. (assembly)
JMC developed a MH-based hydrogen storage and supply system for a reformed natural gas hydrogen refueling station
*Opening ceremony was held February 7, 2002 in Osaka, Japan
MH hydrogen storage and supply system is relatively safe, small, and inexpensive
* AB5 type MH alloy was used
* Operating pressure < 1MPaG
Charge/discharge performance test results
* Charge rate : 30 Nm3 / hr (on target)
* Discharge rate: 25 Nm3 / 9 min (target min)